Dott. Ing. Artur Cokaj ·

Technical guide to industrial odour treatment: pollutants, plasma technologies, reaction time, energy demand, measurement and safety.

A specification requesting a 'plasma odour removal unit' does not describe the process or the performance required. The engineer must know where the exhaust originates, how it is captured, which substances it contains and their concentrations. Wastewater and sludge-handling operations may release hydrogen sulphide, ammonia, mercaptans, amines and volatile organic compounds (VOCs). A biological origin does not establish chemical reactivity. Actual airflow, temperature, humidity, operating schedule, emission requirements and acceptance tests must be defined first.

Identify the pollutants before choosing equipment

A specification requesting a 'plasma odour removal unit' does not describe the process or the performance required. The engineer must know where the exhaust originates, how it is captured, which substances it contains and their concentrations. Wastewater and sludge-handling operations may release hydrogen sulphide, ammonia, mercaptans, amines and volatile organic compounds (VOCs). A biological origin does not establish chemical reactivity. Actual airflow, temperature, humidity, operating schedule, emission requirements and acceptance tests must be defined first.

How plasma, ozone, ions and electrostatic filters differ

Non-thermal plasma (NTP) encompasses electrical discharges that produce energetic electrons, ions and reactive species. Corona and dielectric barrier discharge (DBD) reactors can expose pollutants directly to these species. Ozone generators use discharge processes to make O₃, which can be injected separately. Bipolar ionisers produce positive and negative ions; their presence is not proof of gas-phase odour destruction. Electrostatic precipitators (ESPs) charge and collect particles and aerosols, rather than guaranteeing VOC removal. See ETC's comparison of water scrubbers, electrostatic treatment and ozone.

TechnologyPrimary purposeLimitation to check
Electrostatic precipitatorCollect particles and aerosolsDoes not guarantee gas-phase VOC removal
Ozone generatorProduce and dose O₃Kinetics, contact time and residual ozone
Bipolar ioniserGenerate positive and negative ionsOdour removal needs specific evidence
NTP reactorPromote reactions in the dischargeEnergy, by-products and gas compatibility
AdsorptionSelective retention on a sorbentSaturation, humidity and replacement

Ozone kinetics and residence time

A chemically possible reaction need not proceed rapidly enough in a duct. For direct ethene ozonolysis in an ideal plug-flow model with nearly constant ozone concentration, X = 1 − exp(−k[O₃]τ). The NIST kinetics database provides a reaction constant of approximately 1.67 × 10⁻¹⁸ cm³/(molecule·s) at 298 K. Assuming 1 ppmv O₃ and three seconds of contact, the calculated conversion is only 0.0123%. This illustrative result is not the performance of a plasma reactor or any ETC product.

X = 1 − exp(−k[O₃]τ) • X ≈ 0,0123% (etene/ethene, 1 ppmv O₃, τ = 3 s)

Direct treatment versus remote oxidant generation

In direct treatment, the polluted stream passes through the electrical discharge, potentially exposing electrodes to droplets, deposits and corrosive substances. With remote generation, clean air or oxygen feeds a separate generator and longer-lived oxidants are injected into the main stream. Very short-lived radicals may not survive transport. Mixing quality, residence time and compatibility with the exhaust must therefore be assessed. The configurations are not automatically equivalent.

Specific energy demand: theoretical comparison

Specific energy density (SED) = P/Q, where P is discharge power in watts and Q is airflow in litres per second, has units of J/L. The conversion is 1 J/L = 0.0002778 kWh/m³. The chart presents only calculated electrical power for a hypothetical flow of 10,000 m³/h, excluding fans, cooling and auxiliaries. It neither specifies a required treatment dose nor represents measured ETC equipment consumption.

Theoretical power at 10,000 m³/h versus SED
10 J/L
27.8 kW
30 J/L
83.3 kW
50 J/L
138.9 kW

P (kW) = SED (J/L) × Q (m³/h) / 3,600. Calculated example only; excludes auxiliary equipment.

By-products, humidity and multi-stage treatment

Disappearance of a parent compound does not establish complete mineralisation to CO₂. Partial oxidation may produce aldehydes, ketones, acids or other odorous by-products; some air-fed discharges can also produce oxidised nitrogen species. Humidity changes discharge chemistry, while liquid condensation on insulators can affect electrical stability. Multi-stage designs may combine droplet separation, ESP filtration, selective adsorption and oxidation. Consult the activated-carbon maintenance guide and the peer-reviewed plasma catalysis review.

How to measure odour abatement

EN 13725:2022 defines dynamic olfactometry for odour concentration, expressed in ouE/m³ rather than VOC mass concentration. Odour emission rate = odour concentration × volumetric flow rate, with consistent reference conditions. Representative inlet/outlet measurements require attention to uncertainty, sample stability and, where relevant, residual ozone and reaction products. Read ETC's article on particulate and organic compound removal efficiency.

qₒd = Cₒd × Q [ouE/s]

Electrical safety and explosive atmospheres

High-voltage equipment requires suitable safeguards and maintenance. Where combustible gases, vapours or dust may create explosive atmospheres, the risk must be assessed. Directive 2014/34/EU concerns equipment intended for use in potentially explosive atmospheres; Directive 1999/92/EC concerns worker protection. Remote oxidant generation does not eliminate the need to evaluate the whole installation.

Information needed for a reliable design

Effective selection requires emission sources and extraction method; H₂S, NH₃ and VOC analyses; odour concentration; minimum, normal and peak airflow; temperature; humidity; aerosols; duct losses; operating hours; and measurable discharge targets. The fan and duct network determine what is actually captured. See the ETC extraction and capture guide. Without these parameters, an odour-abatement guarantee cannot be founded on a technology label alone.

Scientific sources and further reading

Primary and scientific references: NIST Kinetics, EN 13725:2022, He et al. (2023), Chang et al. (2022), Toledo and Muñoz (2025), Pasini (2026), and the ATEX equipment and workplace safety directives.

Dott. Ing. Artur Cokaj

Researcher and designer of air treatment technologies

Inventor and holder of industrial invention patent no. 102022000000572.

Technical Manager under D.M. 37/2008, categories A, C, D, E.