ARTURO CP-30

ARTURO CP-30 is the compact version of the ARTURO air purifier: fan, pre-filters, plasma cell and activated carbon in a single stainless steel body.

Compact version

Fumes and odours treated. 3,000 m³/h in a single body.

The machine is placed between the hood and the discharge. Inside are the fan, the inverter and the control panel, already assembled.

The data on this page come from technical dossier ETC-DT-ARTURO-CP-001 Rev. 1.0 · 04/10/2026.

Technical dossier

ARTURO CP-30 is documented by a technical datasheet, an installation, use and maintenance manual, a risk assessment and a treatment analysis. The technical datasheet can be downloaded freely from this page; the manual can be read online and downloaded after signing in.

ETC-DT-ARTURO-CP-001 Rev. 1.0 · 04/10/2026
AISI 304 stainless steelIntegrated fanOn-board inverter

Sizing

The air flow decides the model

ARTURO CP-30 covers air flows up to 3,000 m³/h, with an operating range from 2,400 to 3,000 m³/h. For air flows up to 1,500 m³/h there is ARTURO CP-15. The final check must be made on the actual system.

ETC Group · Air Filtration Technologies

ARTURO CP-30

Compact unit for fumes and odours

Extracts, treats and discharges in a single stainless steel body.

For catering hoods and workstations, dental and goldsmith laboratories and the chemical industry, within the limits of use set out in the manual.

Air flow
3,000 m³/h
Structure
AISI 304 stainless steel
Power supply
220 V · 50 Hz
Weight
150 kg
ARTURO Compact: compact version with fan, control panel and inverter.

Manual

Installation, use and maintenance manual

One manual for ARTURO CP-15 and ARTURO CP-30: safety, installation, commissioning, maintenance, washing of the cell and pre-filters with the detergents, troubleshooting, spare parts and disposal.

English · ETC-DT-ARTURO-CP-001 Rev. 1.0 · 04/10/2026

The problem

Smoke, grease aerosol and odorous compounds

Cooking vapours carry greasy particulate and odorous compounds. If they are not treated, they settle in the ducts and reach the discharge.

01 · DUCTS

Grease settles on the inner surfaces of the extraction system.

02 · FAN

Untreated particulate reaches the fan and fouls it.

03 · ODOUR

The remaining odorous fraction can be smelled outside.

How it works

Three treatment stages and a fan

The air passes through the pre-filters, the electrostatic plasma cell and the activated carbon filter. The fan pushes it towards the discharge.

01 · G4 PRE-FILTERS

They hold back the coarser grease

High-density glass wool filters with electrostatic effect. They must always be fitted: without pre-filters the carbon saturates early.

02 · PLASMA CELL

It charges and collects the particles

The 200 W cell holds grease and smoke on its plates. The oxidising action of cold plasma also works on odours and volatile organic compounds.

03 · ACTIVATED CARBON

It reduces residual odours

Activated carbon filter 4V class F9, 592 × 592 × 292 mm, downstream of the cell. It works on air from which the grease has already been removed.

Extraction

Fan and inverter are on board

The air flow is set with the inverter during commissioning, according to the pressure drops of the actual system.

The fan is an EYNGL 1.5 centrifugal fan in AISI 304 stainless steel, 1.5 kW, 3,520 m³/h at 640 Pa, three-phase motor. The inverter is a Toshiba VF-S15.

1
Hood → duct → ARTURO CP → discharge
Typical layout, to be checked against the system design.
2
Workstation → ARTURO CP
Catering fumes, chemical industry, dental and goldsmith laboratories.
3
ARTURO CP → discharge duct
Not suitable for flammable, explosive, volatile or highly corrosive gases or for diesel engine fumes.
4
Hood → ARTURO CP → wall discharge
Whether the discharge is permitted depends on local regulations.
5
ARTURO CP → accessible maintenance
Leave space to pull out and wash the pre-filters and the cell.

Filter pack

Pre-filters, plasma cell and carbon

In the CP-30 the components have these sizes.

1 × G4
G4 glass wool pre-filters
1 G4 filter, 59.2 × 59.2 × 4.8 cm · electrostatic effect · max temperature 265 °C.
200 W
Electrostatic plasma cell
59.2 × 59.2 × H 30 cm · electrical power 200 W.
3,000 m³/hNominal air flow. Operating range 2,400–3,000 m³/h.

At a glance

Activated carbon
4V · F9 · 592 × 592 × 292 mm
6 kg
Fan
1.5 kW
3,520 m³/h at 640 Pa
Structure
AISI 304
70 dB(A)

The system air flow must stay within the operating range of the model. Outside the range the cell does not work at the correct velocity.

Technical data

ARTURO CP-30

The data are those of the technical dossier. The other model has its own data, see its page.

ModelAir flowFanMotor power supplyInlet / outletInverterW × H × DWeight
ARTURO CP-303,000 m³/h (2,400–3,000)EYNGL 1.5 stainless · 1.5 kW · 3,520 m³/h at 640 Pathree-phaseØ200–250 / Ø200–250 mm1.5 kW · 230 V single-phase → three-phase850 × 1,250 (+600 fan) × 640 mm150 kg

Noise 70 dB(A) · AISI 304 structure · 220 V, 50 Hz power supply with earthing (earth resistance < 2 Ω) · purification efficiency ≥ 90% at nominal air volume · cell power 200 W · equipment resistance < 150 Pa.

Installation

Between the hood and the discharge, with access for maintenance

It is installed indoors, or outdoors with a suitable cover that is not included in the supply.

  • Vertical installation, with body inclination below 2°.
  • Inspection space of more than 0.8 m on the side of the filter access door.
  • Brackets and supports for 150 kg, with a 50% margin.
  • Air velocity in the duct as low as possible, preferably below 19 m/s.

Anti-vibration joint between fan and machine. Flanges sealed with butyl tape or neutral silicone: every leak is a filter bypass.

Limits of use

Conditions stated in the manual

Outside these limits performance drops and the machine can be damaged.

+10 / +40
Ambient temperature
°C
55
Inlet gas
°C max
< 20
Inlet particulate
mg/m³
20–90
Ambient humidity
%

+10 / +40 °C ambient · 55 °C max treated gases · < 20 mg/m³ particulate · humidity 20–90% · altitude < 1,000 m.

Compliance

Machine documentation

The manual contains the risk assessment, the reference standards and the template of the EC declaration of conformity.

  • Low Voltage 2014/35/EU
  • Electromagnetic Compatibility 2014/30/EU
  • UNI EN ISO 13857:2020 · CEI EN 60204 · CEI EN 60335
  • Risk assessment according to UNI EN ISO 12100
  • ISO 16890 filter classification

Whether the installation is permitted also depends on local regulations. Design, permits and dealings with the authorities remain the responsibility of the client and of qualified technicians. ETC Group acts as supplier only.

Request an assessment

Tell us the air flow and the type of cooking

With these data we check which model is suitable and how to connect it to the system.

ETC GROUP S.r.l. · Strada delle Campagne 10, 61010 Tavullia (PU), Italia · P.IVA IT04083110405 · REA PS-196574
ETC-DT-ARTURO-CP-001 Rev. 1.0 · 04/10/2026
Technical data and availability may change without notice. The values given in the manual supplied with the machine apply.